toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Chen, H.; Xiong, X.; Geng, X.; Twedt, K. url  doi
openurl 
  Title Stray-light correction and prediction for Suomi National Polar-orbiting Partnership visible infrared imaging radiometer suite day-night band Type Journal Article
  Year 2019 Publication (up) Journal of Applied Remote Sensing Abbreviated Journal J. Appl. Rem. Sens.  
  Volume 13 Issue 02 Pages 1  
  Keywords Instrumentation; Remote Sensing  
  Abstract The Suomi National Polar-orbiting Partnership visible infrared imaging radiometer suite instrument has successfully operated since its launch in October 2011. Stray-light contamination is much larger than prelaunch expectations, and it causes a major decrease in quality of the day-night band night imagery when the spacecraft is crossing the Northern or Southern day-night terminators. The stray light can be operationally estimated using Earth-view data that are measured over dark surfaces during the new moon each month. More than 7 years of nighttime images have demonstrated that the stray-light contamination mainly depends on the Earth–Sun–spacecraft geometry, so its intensity is generally estimated as a function of the satellite zenith angle. In practice, stray-light contamination is also detector- and scan-angle-dependent. Previous methods of stray-light prediction generally rely on using the known stray light level from the same month in the previous year, when the Earth–Sun–spacecraft geometries had been similar. We propose a new method to predict stray-light contamination. The Kullback–Leibler similarity metric is used as a method to combine data from multiple years with appropriate adjustments for degradation and geometry drifts in order to calculate a fused stray-light contamination correction. The new method provides an improved prediction of stray-light contamination compared to the existing methods and may be considered for future use in the real-time NASA Level-1B products.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1931-3195 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2517  
Permanent link to this record
 

 
Author Bierman, A.; Figueiro, M.G.; Rea, M.S. url  doi
openurl 
  Title Measuring and predicting eyelid spectral transmittance Type Journal Article
  Year 2011 Publication (up) Journal of Biomedical Optics Abbreviated Journal J Biomed Opt  
  Volume 16 Issue 6 Pages 067011  
  Keywords Instrumentation; Human Health  
  Abstract The purpose of the present study was to objectively quantify the spectral transmittance of the eyelid. Reported here are data acquired using a technique that was developed to provide practical and accurate measurements of eyelid transmittance across the visible portion of the electromagnetic spectrum. The empirical data were analyzed in terms of the absorption and scattering characteristics of the constituents of skin to develop a method for predicting eyelid transmission. Results showed that the eyelid has a much higher optical density at short wavelengths than previously published. The mean +/- standard deviation (s.d.) optical density of the eyelid from 450 to 650 nm was 2.1 +/- 0.3 with an optical density range among subjects of approximately 1.0. The study results indicate that skin pigmentation is poorly correlated with eyelid transmission; eyelid transmission is most affected by wavelength-independent macromolecules in the eyelid as well as its overall thickness.  
  Address Rensselaer Polytechnic Institute, Lighting Research Center, 21 Union Street, Troy, New York 12180, USA  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1083-3668 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:21721832 Approved no  
  Call Number LoNNe @ kyba @ Serial 1530  
Permanent link to this record
 

 
Author Voigt, L.P.; Reynolds, K.; Mehryar, M.; Chan, W.S.; Kostelecky, N.; Pastores, S.M.; Halpern, N.A. url  doi
openurl 
  Title Monitoring sound and light continuously in an intensive care unit patient room: A pilot study Type Journal Article
  Year 2016 Publication (up) Journal of Critical Care Abbreviated Journal Journal of Critical Care  
  Volume 38 Issue 21 Pages 5952-5961  
  Keywords Instrumentation; Human Health  
  Abstract Purpose

To determine the feasibility of continuous recording of sound and light in the intensive care unit (ICU).

Materials and Methods

Four one-hour baseline scenarios in an empty ICU patient room by day and night (doors open or closed and maximal or minimal lighting) and two daytime scenarios simulating a stable and unstable patient (quiet or loud devices and staff) were conducted. Sound and light levels were continuously recorded using a commercially available multisensor monitor and transmitted via the hospital's network to a cloud-based data storage and management system.

Results

The empty ICU room was loud with similar mean sound levels for the day and night simulations of 45–46 dBA. Mean levels for maximal lighting during day and night ranged from 1306–1812 lux and mean levels for minimum lighting were 1–3 lux. The mean sound levels for the stable and unstable patient simulations were 61 and 81 dBA, respectively. The mean light levels were 349 lux for the stable patient and 1947 lux for the unstable patient.

Conclusions

Combined sound and light can be continuously and easily monitored in the ICU setting. Incorporating sound and light monitors in ICU rooms may promote an enhanced patient and staff centered healing environment.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0883-9441 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1614  
Permanent link to this record
 

 
Author Mills, S.; Miller, S. url  doi
openurl 
  Title VIIRS Day/Night Band--Correcting Striping and Nonuniformity over a Very Large Dynamic Range Type Journal Article
  Year 2016 Publication (up) Journal of Imaging Abbreviated Journal J. Imaging  
  Volume 2 Issue 1 Pages 9  
  Keywords Instrumentation  
  Abstract The Suomi National Polar-orbiting (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day-Night Band (DNB) measures visible and near-infrared light extending over seven orders of magnitude of dynamic range. This makes radiometric calibration difficult. We have observed that DNB imagery has striping, banding and other nonuniformities—day or night. We identified the causes as stray light, nonlinearity, detector crosstalk, hysteresis and mirror-side variation. We found that these affect both Earth-view and calibration signals. These present an obstacle to interpretation by users of DNB products. Because of the nonlinearity we chose the histogram matching destriping technique which we found is successful for daytime, twilight and nighttime scenes. Because of the very large dynamic range of the DNB, we needed to add special processes to the histogram matching to destripe all scenes, especially imagery in the twilight regions where scene illumination changes rapidly over short distances. We show that destriping aids image analysts, and makes it possible for advanced automated cloud typing algorithms. Manual or automatic identification of other features, including polar ice and gravity waves in the upper atmosphere are also discussed. In consideration of the large volume of data produced 24 h a day by the VIIRS DNB, we present methods for reducing processing time.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2313-433X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1400  
Permanent link to this record
 

 
Author Sánchez de Miguel, A.; Bará, S.; Aubé, M.; Cardiel, N.; Tapia, C.E.; Zamorano, J.; Gaston, K.J. url  doi
openurl 
  Title Evaluating Human Photoreceptoral Inputs from Night-Time Lights Using RGB Imaging Photometry Type Journal Article
  Year 2019 Publication (up) Journal of Imaging Abbreviated Journal J. Imaging  
  Volume 5 Issue 4 Pages 49  
  Keywords Human Health; Remote Sensing; Instrumentation  
  Abstract Night-time lights interact with human physiology through different pathways starting at the retinal layers of the eye; from the signals provided by the rods; the S-, L- and M-cones; and the intrinsically photosensitive retinal ganglion cells (ipRGC). These individual photic channels combine in complex ways to modulate important physiological processes, among them the daily entrainment of the neural master oscillator that regulates circadian rhythms. Evaluating the relative excitation of each type of photoreceptor generally requires full knowledge of the spectral power distribution of the incoming light, information that is not easily available in many practical applications. One such instance is wide area sensing of public outdoor lighting; present-day radiometers onboard Earth-orbiting platforms with sufficient nighttime sensitivity are generally panchromatic and lack the required spectral discrimination capacity. In this paper, we show that RGB imagery acquired with off-the-shelf digital single-lens reflex cameras (DSLR) can be a useful tool to evaluate, with reasonable accuracy and high angular resolution, the photoreceptoral inputs associated with a wide range of lamp technologies. The method is based on linear regressions of these inputs against optimum combinations of the associated R, G, and B signals, built for a large set of artificial light sources by means of synthetic photometry. Given the widespread use of RGB imaging devices, this approach is expected to facilitate the monitoring of the physiological effects of light pollution, from ground and space alike, using standard imaging technology.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2313-433X ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number GFZ @ kyba @ Serial 2294  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: