Author Price, B.; Baker, E. url  doi
openurl 
  Title NightLife: A cheap, robust, LED based light trap for collecting aquatic insects in remote areas Type Journal Article
  Year 2016 Publication Biodiversity Data Journal Abbreviated Journal Bdj  
  Volume 4 Issue Pages (down) e7648  
  Keywords Animals; Ecology; Lighting  
  Abstract Background

There are approximately one hundred thousand aquatic insect species currently known to science and this figure is likely a significant underestimation. The ecology of aquatic insect groups has been studied due to their role as bioindicators of water quality and in the case of Diptera, their role as vectors of disease. Light trapping targets emergent adults, using mercury vapour bulbs or actinic fluorescent tubes, however these light sources are unsuitable for sampling remote regions due to their power requirements, which limit their mobility. Most insects studied have three types of photoreceptors corresponding to UV, blue and green light.

New information

We describe the NightLife: a cheap, robust, portable, LED based light source which targets insect trichromatic vision, is capable of autonomous operation and is powered by a single AA battery. Field trials show that the NightLife is capable of collecting sufficient samples of 12 insect orders, including all aquatic orders commonly collected by traditional light trapping and compares favourably with actinic fluorescent tubes and white LEDs. Future development in LED technology will likely result in LEDs replacing traditional light sources for collecting insects more widely.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1314-2836 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1398  
Permanent link to this record
 

 
Author Morag, I.; Ohlsson, A. url  doi
openurl 
  Title Cycled light in the intensive care unit for preterm and low birth weight infants Type Journal Article
  Year 2016 Publication The Cochrane Database of Systematic Reviews Abbreviated Journal Cochrane Database Syst Rev  
  Volume 8 Issue Pages (down) Cd006982  
  Keywords Human Health  
  Abstract BACKGROUND: Potential benefits and harms of different lighting in neonatal units have not been quantified. OBJECTIVES: * To determine effectiveness and safety of cycled light (CL) (approximately 12 hours of light on and 12 hours of light off) for growth in preterm infants at three and six months' corrected age (CA).* In separate analyses, to compare effects of CL with those of irregularly dimmed light (DL) or near darkness (ND), and effects of CL with those of continuous bright light (CBL), on growth in preterm infants at three and six months' CA.* To assess, in subgroup analyses, the effectiveness and safety of CL (vs control interventions (DL, ND and CBL)) introduced at different postmenstrual ages (PMAs) – before 32 weeks', at 32 weeks' and from 36 weeks' PMA – and to compare effectiveness and safety of CL for small for gestational age (GA) infants versus appropriately grown infants. SEARCH METHODS: We used the standard search strategy of the Cochrane Neonatal Review Group to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 12), MEDLINE via PubMed (1966 to January 2016), Embase (1980 to January 2016) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL; 1982 to January 2016). We searched clinical trials databases, conference proceedings and reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. SELECTION CRITERIA: Randomised or quasi-randomised trials of CL versus ND or CBL in preterm and low birth weight infants. DATA COLLECTION AND ANALYSIS: We performed data collection and analyses according to the methods of the Cochrane Neonatal Review Group. We used the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to assess the quality of evidence. MAIN RESULTS: We identified one additional study enrolling 38 participants for inclusion in this update, for a total of nine studies reporting on 544 infants. In general, the quality of the studies was low, mainly owing to lack of blinding and small sample sizes.Six studies enrolling 424 infants compared CL versus ND. No study reported on weight at three or six months. One study (n = 40) found no statistically significant difference in weight at four months between CL and ND groups. In another study (n = 62), the ratio of day-night activity before discharge favoured the CL group (mean difference (MD) 0.18, 95% confidence interval (CI) 0.17 to 0.19), indicating 18% more activity during the day than during the night in the CL group compared with the ND group. Two studies (n = 189) reported on retinopathy of prematurity (stage >/= 3) and reported no statistically significant differences between CL and ND groups (typical risk ratio (RR) 0.53, 95% CI 0.25 to 1.11, I2 = 0%; typical risk difference (RD) -0.09, 95% CI -0.19 to 0.01, I2 = 0%). Two studies (n = 77) reported length of hospital stay (days) and noted a significant reduction in length of stay between CL and ND groups favouring the CL group (weighted mean difference (WMD) -13 days, 95% CI -23 to -2, I2 = 0%; no heterogeneity). The quality of the evidence according to GRADE was low for this outcome. One study (n = 37) reported less crying at 11 weeks' corrected age (CA) in the CL group compared with the ND group (MD -0.57 hours/24 h, 95% CI -1.09 to -0.05). Tests for heterogeneity were not applicable.Three studies enrolling 120 infants compared CL versus CBL. Two studies (n = 79) reported significantly shorter length of stay in the CL group compared with the CBL group (WMD -16.5 days, 95% CI -26.2 to -6.8, I2 = 0%; no heterogeneity). The quality of the evidence according to GRADE was low for this outcome. One study (n = 41) reported higher mean weight at three months' CA among infants cared for in the CL nursery (P value < 0.02) and a lower mean number of hours spent awake in 24 hours at three months of age (P value < 0.005). Data could not be entered into RevMan or GRADE. One study (n = 41) reported shorter time on the ventilator in the CL compared with the CBL group (MD -18.2 days, 95% CI -31.40 to -5.0). One study (n = 41) reported a shorter time to first oral feeding in the CL group (MD -6.8 days, 95% CI -13.29 to -0.31). We identified no safety issues. AUTHORS' CONCLUSIONS: Trials assessing the effects of CL have enrolled 544 infants. No study reported on our primary outcome of weight at three or six months. Results from one additional study strengthen our findings that CL versus CBL shortens length of stay, as does CL versus ND. The quality of the evidence on both comparisons for this outcome according to GRADE was low. Future research should focus on comparing CL versus ND.  
  Address The Edmond & Lily Safra Children's Hospital Sheba Medical Center, Tel Hashomer, Israel  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1361-6137 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:27508358 Approved no  
  Call Number LoNNe @ kyba @ Serial 1506  
Permanent link to this record
 

 
Author Rybnikova, N.A.; Portnov, B.A. url  doi
openurl 
  Title Outdoor light and breast cancer incidence: a comparative analysis of DMSP and VIIRS-DNB satellite data Type Journal Article
  Year 2016 Publication International Journal of Remote Sensing Abbreviated Journal International Journal of Remote Sensing  
  Volume 38 Issue 21 Pages (down) 5952-5961  
  Keywords Human Health  
  Abstract Several population-level studies explored the association between breast cancer (BC) incidence and artificial light-at-night (ALAN), and found higher BC rates in more lit areas. Most of these studies used ALAN satellite data, available from the United States Defence Meteorological Satellite Program (US-DMSP), while, in recent years, higher-resolution ALAN data sources, such as Visible Infrared Imaging Radiometer Suite Day-Night Band (VIIRS-DNB), have become available. The present study aims to determine whether the use of different ALAN data sources may affect the BC–ALAN association. As the test case, we use data on BC incidence rates in women residing in the Greater Haifa Metropolitan Area (GHMA; Israel), matching them with US-DMSP and VIIRS-DNB data on ALAN intensities, and controlling for several potential confounders, including age, fertility, and socio-economic status (SES). Both ordinary least squares (OLS) and spatial dependency models were used in the analysis. ALAN emerged as a stronger predictor of BC rates in models based on better-resolution VIIRS-DNB estimates (t > 6.035; p < 0.01) than in models based on coarser US-DMSP data (t < 4.196; p < 0.01).  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0143-1161 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1552  
Permanent link to this record
 

 
Author Voigt, L.P.; Reynolds, K.; Mehryar, M.; Chan, W.S.; Kostelecky, N.; Pastores, S.M.; Halpern, N.A. url  doi
openurl 
  Title Monitoring sound and light continuously in an intensive care unit patient room: A pilot study Type Journal Article
  Year 2016 Publication Journal of Critical Care Abbreviated Journal Journal of Critical Care  
  Volume 38 Issue 21 Pages (down) 5952-5961  
  Keywords Instrumentation; Human Health  
  Abstract Purpose

To determine the feasibility of continuous recording of sound and light in the intensive care unit (ICU).

Materials and Methods

Four one-hour baseline scenarios in an empty ICU patient room by day and night (doors open or closed and maximal or minimal lighting) and two daytime scenarios simulating a stable and unstable patient (quiet or loud devices and staff) were conducted. Sound and light levels were continuously recorded using a commercially available multisensor monitor and transmitted via the hospital's network to a cloud-based data storage and management system.

Results

The empty ICU room was loud with similar mean sound levels for the day and night simulations of 45–46 dBA. Mean levels for maximal lighting during day and night ranged from 1306–1812 lux and mean levels for minimum lighting were 1–3 lux. The mean sound levels for the stable and unstable patient simulations were 61 and 81 dBA, respectively. The mean light levels were 349 lux for the stable patient and 1947 lux for the unstable patient.

Conclusions

Combined sound and light can be continuously and easily monitored in the ICU setting. Incorporating sound and light monitors in ICU rooms may promote an enhanced patient and staff centered healing environment.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0883-9441 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1614  
Permanent link to this record
 

 
Author Polivka, T.N.; Wang, J.; Ellison, L.T.; Hyer, E.J.; Ichoku, C.M. url  doi
openurl 
  Title Improving Nocturnal Fire Detection With the VIIRS Day-Night Band Type Journal Article
  Year 2016 Publication IEEE Transactions on Geoscience and Remote Sensing Abbreviated Journal IEEE Trans. Geosci. Remote Sensing  
  Volume 54 Issue 9 Pages (down) 5503-5519  
  Keywords Remote Sensing  
  Abstract Building on existing techniques for satellite remote sensing of fires, this paper takes advantage of the day-night band (DNB) aboard the Visible Infrared Imaging Radiometer Suite (VIIRS) to develop the Firelight Detection Algorithm (FILDA), which characterizes fire pixels based on both visible-light and infrared (IR) signatures at night. By adjusting fire pixel selection criteria to include visible-light signatures, FILDA allows for significantly improved detection of pixels with smaller and/or cooler subpixel hotspots than the operational Interface Data Processing System (IDPS) algorithm. VIIRS scenes with near-coincident Advanced Spaceborne Thermal Emission and Reflection (ASTER) overpasses are examined after applying the operational VIIRS fire product algorithm and including a modified “candidate fire pixel selection” approach from FILDA that lowers the 4-&#956;m brightness temperature (BT) threshold but includes a minimum DNB radiance. FILDA is shown to be effective in detecting gas flares and characterizing fire lines during large forest fires (such as the Rim Fire in California and High Park fire in Colorado). Compared with the operational VIIRS fire algorithm for the study period, FILDA shows a large increase (up to 90%) in the number of detected fire pixels that can be verified with the finer resolution ASTER data (90 m). Part (30%) of this increase is likely due to a combined use of DNB and lower 4-&#956;m BT thresholds for fire detection in FILDA. Although further studies are needed, quantitative use of the DNB to improve fire detection could lead to reduced response times to wildfires and better estimate of fire characteristics (smoldering and flaming) at night.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0196-2892 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number LoNNe @ kyba @ Serial 1781  
Permanent link to this record
Select All    Deselect All
 |   | 